phenomena |
reasons |
handling measures |
the waist wheel does not run |
1、 The dirt blocks the pipes 2、The tested liquid is frozen |
1、 To clean the pipe、filter and flow meter 2、 To resolve the liquid |
The waist wheel runs but the needles do not move or stop at times |
1、The fork of gauge outfit is out of line The dirt goes into the speed charger of gauge
outfit 3、The speed charger disjoints |
To discharge the gauge outfit and to use hands to run the fork.If the instrument moves, it proves that the connection of gauge outfit and bearing is broken; if not, we have to check step by step. |
Turning to sealed coupling shaft with oil leakage |
The gasket wears down |
To tighten the gland or replace the gasket |
The difference between the compensator and the small flow is partial to be negative |
The waist wheel collides with the shell, along with the abrasion of bearing or the immobilization to the main body of drive gear moves the position |
To change the bearing and check the drive gear to see if the wheel body works; to fasten the screw of gear to see whether it loosens or not |
The error changes greatly |
1、 The pulsing of liquid is rather big 2、 It contains gas
|
1、To reduce the pulsing 2、To add the getter device |